Tag Archive: temperature monitoring

MadgeTech’s New Software Upgrade Features Cloud Access

 

Built-In Access to Data from any Cloud-Enabled Device!

CHESTERLAND OH—April 22, 2015

MadgeTech has just announced a new software upgrade complete with built-in access to MadgeTech’s Cloud Service! To get access to all the new features, download the upgrade on our Madgetech Downloads page at http://www.dataloggerinc.com/downloads/madgetech.php. Read more about the new version at http://bit.ly/1OG6eeO.

Diagnose Bearing Failure Before it Happens!

Wireless Data Loggers Monitor Bearing Temperature, Vibration and more

CHESTERLAND OH—February 25, 2015

Another unscheduled shutdown—a bearing just failed and suddenly everyone’s on the hook! This scenario plays out every day in factories and plants across the country, but it doesn’t have to happen to you. At CAS DataLoggers we offer wireless monitoring solutions to monitor and analyze bearing temperature and vibration data to warn of developing bearing damage. Learn more about how to save your business time and money in our latest Press Release at http://www.dataloggerinc.com/content/news/press_releases/843/diagnose_bearing_failure_before_it_happens/.

Monitoring Energy Efficiency in a Display Home

CAS Dataloggers recently provided the datalogging solution for a large manufacturer of thermally efficient and lightweight building panels whose insulated products were used extensively in the construction of a highly energy-efficient home. The manufacturer wanted to set up continual temperature monitoring over an extended period of time that would demonstrate all the energy and cost benefits of its thermally-efficient materials; the home would initially be used for display purposes, after which time it would be occupied for a full year to validate its high energy efficiency rating. Read the entire article here on our applications note page.

T&D RTR-500GSM Basic GSM Modem Setup Guide

Enable Remote Monitoring with T&D Cellular Base Station
CHESTERLAND OH—January 26, 2012

The RTR-500GSM is a Mobile Base Station with built-in wireless communication via GSM phone network capabilities. It can be used as a Base Unit for T&D’s popular RTR-500 wireless datalogger series, and when in communication range for GSM cellular phone service, the device can transmit data and warnings in remote locations where a LAN connection is impossible, making it ideal for tracking data while in transport. Warning reports can also be sent via e-mail or SMS to specified e-mail addresses, enabling the user to always stay appraised of changes in measurement readings. Read the entire article on our T&D tutorials page.

Data Monitoring for a Rural Development Charity

Using the dataTaker DT80 Intelligent Universal Input Datalogger
CHESTERLAND OH—December 28, 2011

Datataker Pty Ltd, with integration from Engineers Without Borders Australia, recently provided the datalogging solution for RIDS-Nepal (Rural Integrated Development Services in Nepal), a Nepali non-profit, non-government organization with the stated mission to improve the overall living conditions of the impoverished high-altitude communities in the Nepal Himalayas. RIDS was involved in holistic community development projects and field-based research projects financed by donations from individuals and charities. This newly-enacted community development consisted of providing every home in the village of Tulin with a pit latrine, a smokeless metal stove, and basic indoor lighting as well as access to clean drinking water. Some of the technologies RIDS-Nepal developed with Kathmandu University and the local Nepali industry included high altitude solar water heaters, slow sand water filters, and high altitude greenhouses and solar driers. Data monitoring formed an important part of RIDS’ long-term humanitarian programs, which was unfortunately hardly ever done by other community development organizations due to the preferred short-term project approach preferred by most donors. In particular, power/energy generating projects, such as solar PV village electrification systems and pico-hydro power plants, were important to monitor since these villages were gaining access to electricity for the first time in their history. RIDS-Nepal needed to know how their implemented power generating systems performed over the various seasons and years, so several of these energy generation systems and infrastructures needed to be monitored. The Tulin village project therefore required a flexible yet cost-effective datalogging solution capable of measuring a wide range of physical values including temperature, current, and voltage.

Project management installed a dataTaker DT80 Intelligent Universal Datalogger in Tulin village and connected it to a wide array of sensors measuring temperature, current, and voltage. A special protective casing was fabricated for the monitoring equipment—a special precaution taken so that the ever-present mice couldn’t get access to the wires! The DT80 was separately powered with two 20WP Solar PV modules and a 30Ah sealed deep-cycle battery. A program specifically written for the dataTaker device was loaded and tested, and then the sensors’ cabling was carefully connected to the data logger.

After implementation, long-term data monitoring of defined implemented projects was conducted. For example, considering just the solar PV data monitoring system installed in the village, RIDS-Nepal measured and calculated 22 different parameters with the DT80 data logger in order to understand the system’s detailed performance over the years. These fundamental parameters included ambient temperature, battery-bank temperature, PV cell temperature, solar PV array current, solar PV array voltage, battery-bank current in/out and WLED load voltage and current. Several different sensor types were used including T-type thermocouples, a SolData pyranometer, and HXS 20-NP current transducers. The solar PV array, battery-bank, and WLEDs were all connected directly to the dataTaker datalogger, which handled all the voltage readings.

RIDS-Nepal and its Tulin village project benefitted in several key ways following installation of the DT80 Intelligent Universal Input Datalogger. The dataTaker device monitored all the necessary parameters including temperature, voltage and current, and also connected to the pyranometer to measure irradiance. Additionally, this versatility came at a low enough price to easily fit into the project’s limited budget.

In order to learn from practical field projects, RIDS-Nepal developed its own databank over the course of 2 years. All 11 monitored and recorded power/energy generating systems and several of the finished infrastructures’ data were made available through the databank. In this way RIDS-Nepal hoped to share and support other, like-minded professional and organizations involved in holistic community development projects. Using the datalogger’s readings as a baseline, projects became more relevant and more sustainable for the long-term benefit of the local people for whom all the effort was meant.

Research & development based on the village baseline surveys, follow-up surveys, and practical experience resulted in the development and local manufacturing of new, contextualized technologies and infrastructures, as well as educational methods & teaching materials for Non-Formal-Education (NFE) classes for women and unschooled children. This multi-faceted project took the local people’s own identified needs seriously by addressing them through context-relevant projects and programs, and the readings helped show that even minimal access to improved energy services such as improved cooking, room heating, hot water and basic indoor lighting brought enormous improvements to the community.

Check out the dataTaker DT80 Intelligent Universal data logger product page here.

For more information on the DT80 Intelligent Universal data logger, other dataloggers in the highly successful dataTaker line, or to find the ideal solution for your application-specific needs, contact a CAS Data Logger Applications Specialist at (800) 956-4437 or visit the website at www.DataLoggerInc.com.

Contact Information:
CAS DataLoggers, Inc.
12628 Chillicothe Road
Chesterland, Ohio 44026
(440) 729-2570
(800) 956-4437
sales@dataloggerinc.com
http://www.dataloggerinc.com